The average % of lamp life chart indicates the average age of lamps in a system based on the number of lamps each year. The table below shows an example of this calculated for a system with a 100 lamps, each with a 3000 hour rated life, where 25% of the lamps are replaced every 2 years.
Lamp Burn Hours | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Year | 0 | 3,000 | 6,000 | 9,000 | 12,000 | 15,000 | 18,000 | 21,000 | Lamp Hours | Ave |
1 | 100.0% | 300,000 | 25% | |||||||
2 | 25.0% | 75.0% | 450,000 | 38% | ||||||
3 | 25.0% | 75.0% | 750,000 | 63% | ||||||
4 | 25.0% | 25.0% | 50.0% | 750,000 | 63% | |||||
5 | 25.0% | 25.0% | 50.0% | 1,050,000 | 88% | |||||
6 | 25.0% | 25.0% | 25.0% | 25.0% | 900,000 | 75% | ||||
7 | 25.0% | 25.0% | 25.0% | 25.0% | 1,200,000 | 100% | ||||
8 | 25.0% | 25.0% | 25.0% | 25.0% | 900,000 | 75% | ||||
9 | 25.0% | 25.0% | 25.0% | 25.0% | 1,200,000 | 100% | ||||
10 | 25.0% | 25.0% | 25.0% | 25.0% | 900,000 | 75% |