Exitance is the converse of illuminance . Rather than the density of light incident upon a surface, exitance is the density of light leaving a surface.
In practical terms, exitance (M) may be calculated by multiplying the illuminance on a surface by the reflectance of that surface. The units of exitance are lumens/square foot and lumens/square meter. |
|
|
Visual can report exitance by using Properties to change the Measurement Type and assign a Reflectance to a Calculation Zone after it is created. Select the Calculation Zone, click the Measurement list in the Calculation panel in the Properties tab and select "Exitance ", then specify a Reflectance. Right-click or press Enter to apply the changes. Visual will immediately apply the Reflectance without recalculation. |
|
|
Exitance can be displayed in the Rendered Display Mode By selecting from the Display Menu on the Calculations tab . (This is not the same as the Display button on the Home tab .) |
|